Electronic oval gears flow meter with pulse transmitter, body in IXEF. Suitable for the use with water-based fluids and AdBlue® (DEF). Appropriate to the use in combination with electronic oil monitoring systems by the use of an external receiver.
Art. | Connections | Max flow (l/min) | Operating temperature range | Max working pressure | Accuracy | Number of pulses | Weight |
2716 | M 1/2″ BSP | 35 | +5°C +50°C | 30 bar | +/- 0,5% | 78/l | 0,4 kg |
Electronic oval gears flow meter with pulse transmitter, suitable for oil and antifreeze. Appropriate to the use in combination with electronic oil monitoring systems by the use of an external receiver.
Art. | Connections | Max flow (l/min) | Operating temperature range | Max working pressure | Accuracy | Number of pulses | Weight |
2954 | M 1/2″ BSP | 35 | +5°C +50°C | 70 bar | +/- 0,5% | 78/l | 0,6 kg |
Electronic oval gears fl ow meter with pulse transmitter, suitable for oil, diesel and antifreeze, including a 24 VDC – solenoid valve, an in-line 150 μm cartridge filter and a wall bracket.
Art.no. 8730/RF Version with wireless data transmission.
Art.no. 8733 Electronic oval gears flow meter with pulse transmitter, such as art. no. 8730, for grease.
Art.no. 8733/RF Version with wireless data transmission.
Art. | Connections | Max flow (l/min) | Operating temperature range | Max working pressure | Accuracy | Number of pulses | Weight | Dimensions (LxWxH) (mm) |
8730 8730RF | F 1/2″ BSP | 35 | +5°C +110°C | 100 bar (1450 psi) | +/- 0,5% | 100l | 1,5 kg | 120x120x160 |
8733 8733RF | 250 bar (3600 psi) |
Electronic oval gears flow meter with pulse transmitter, suitable for oil, diesel and antifreeze, including a 24 VDC – solenoid valve, an in-line 150 μm cartridge fi lter and a wall bracket. Appropriate to the use in combination with electronic oil monitoring systems by the use of an external receiver.
Art.no. 8731/RF Version with wireless data transmission.
Art. | Connections | Max flow (l/min) | Operating temperature range | Max working pressure | Accuracy | Number of pulses | Weight | Dimensions (LxWxH) (mm) |
8731 | F 1″ BSP | 80 | +5°C +110°C | 100 bar | +/- 0,5% | 78/l | 2,5 kg | 120x120x175 |
Electronic oval gears flow meter with pulse transmitter, suitable for oil, diesel and antifreeze, including a 24 VDC – solenoid valve, an in-line 150 μm cartridge filter, a built-in display and a wall bracket. Appropriate to the use in combination with electronic oil monitoring systems by the use of an external receiver
Art. | Connections | Max flow (l/min) | Operating temperature range | Max working pressure (bar) | Accuracy | Number of pulses | Weight | Dimensions (LxWxH) (mm) |
8732 | F 1/2″ BSP | 35 | +5°C / + 110°C | 100 | +/- 0.5% | 100/l | 1.5 kg | 120x120x160 |
Electronic oval gears flow meter with pulse transmitter, body in IXEF, including a stainless steel 24 VDC – solenoid valve, an in-line 150 μm cartridge filter and a wall bracket. Suitable for the use with water-based fluids and AdBlue® (DEF). Appropriate to the use in combination with electronic oil monitoring systems by the use of an external receiver.
Art.no. 8735/RF Version with wireless data transmission.
Art. | Connections | Max flow (l/min) | Operating temperature range | Max working pressure | Accuracy | Number of pulses | Weight | Dimensions (LxWxH) (mm) |
8735 | F 1/2″ BSP | 35 | +5°C +110°C | 10 bar (145 psi) | +/- 0,5% | 95/l | 1.5 kg | 120x120x160 |
Electronic oval gears flow meter with pulse transmitter, body in IXEF, including a stainless steel solenoid valve. Suitable for the use with water-based fluids and AdBlue® (DEF). Appropriate to the use in combination with electronic oil monitoring systems by the use of an external receiver.
Art. | Connections | Max flow (l/min) | Operating temperature range | Max working pressure | Accuracy | Number of pulses | Weight |
2716 | M 1/2″ BSP | 35 | +5°C +70°C | 30 bar | +/- 0,5% | 78/l | 0,4 kg |
Electronic oval gears high delivery flow meter with pulse transmitter, suitable for oil, diesel and antifreeze. Appropriate to the use in combination with electronic oil monitoring systems by the use of an external receiver.
Art. | Connections | Max flow (l/min) | Operating temperature range | Max working pressure | Accuracy | Number of pulses | Weight |
2853 | F 1″ BSP | 70 | +5°C +50°C | 70 bar | +/- 0,5% | 50/l | 1,6 kg |