Electronic Fluid Monitoring System

The system FLUID KEEPER 8 MULTIDISPENSE offers plenty of additional functions compared to the basic version. These are:
– Each control unit allows the monitoring of up to 8 dispensing points and the simultaneous dispense of lubricants in various of them;
– On the connected PC the required measuring unit (liters, gallons, pints, quarts) can quickly be chosen;
– Data entry with a bar code reader (optional) helps to avoid possible errors and to increase operations velocity;
– Wide monitoring of dispensing jobs and dispensing quantities: preset, free or serial mode;
– Management of suppliers: possibility to automatically send emails when predefined minimum levels in lubricants storage tanks have been reached; the operator can send emails to different email addresses and to different suppliers;
– Intuitive graphical interface software.

Control unit FLUID KEEPER 8 MULTIDISPENSE

Art. 8876

Control unit FLUID KEEPER 8 MULTIDISPENSE with alphanumerical keyboard and display. One control unit is necessary per 8 dispensing points and allows also simultaneous dispensing in various dispensing points. There can be installed up to 8 control units in the system.

Art. 8877
Alphanumerical keyboard with display without memory that can be installed optionally and allows to activate any of the connected dispensing points of the system. There can be installed up to 40 of these keyboards in the system.
Art. 6532
Transformer / stabilizer 110-230 VAC – 24 VDC, 7,5 A, IP 55, for the power supply of the control unit art. no. 8876, with protection of internal components in case of voltage fluctuations. One transformer / stabilizer is necessary for each control unit.
Art. 6528
Transformer / stabilizer 110-230 VAC – 24 VDC, 5 A, IP 55, for the power supply of the control unit art. no. 8877. One transformer / stabilizer is necessary for each control unit.
Art. 8854
Thermal printer (optional), can be connected to the CANBUS of the control unit. Required for printing a ticket of each individual dispense.

Bar code reader for FLUID KEEPER 8 MULTIDISPENSE system

Art. 8795

Bar code reader for FLUID KEEPER 8 MULTIDISPENSE system. Allows to scan all data that can be read by the software. The bar code reader must be connected to an alfanumerical keyboard unit, art. no. 8877. With only one quick transaction all necessary data can be read, avoiding like that any possible errors eventually occurring when entering the data manually on the keyboard.

Electronic oval gears flow meter with pulse transmitter

Art. 8730 – 8731

Electronic oval gears flow meter with pulse transmitter, suitable for oil and diesel, including a solenoid valve, an in-line 150 μm filter and a wall bracket.

Art.ConnectionsMax flow (l/min)Operating temperature rangeMax working pressure (bar)AccuracyNumber of pulsesWeight
8730F 1/2″ BSP35+5°C / + 110°C100+/- 0,5%100/l1,5 kg
8731F 1″ BSP80+5°C / + 110°C100+/- 0,5%100/l2,5 kg
art 8735 flexbimec

Art. 8735

Electronic oval gears flow meter with pulse transmitter, body in IXEF, including a stainless steel 24 VDC – solenoid valve, an in-line 150 μm cartridge filter and a wall bracket. Suitable for the use with water-based fluids and AdBlue® (DEF).

Art.ConnectionsMax flow (l/min)Operating temperature rangeMax working pressure (bar)AccuracyNumber of pulsesWeight
87351/2″ BSP (F)35+5°C / + 110°C10+/- 0,5%95/l1,5 kg

Art. 8732

Electronic oval gears flow meter with pulse transmitter, suitable for oil and diesel, including a solenoid valve, an in-line 150 μm filter, a built-in display and a wall bracket.

Art.ConnectionsMax flow (l/min)Operating temperature rangeMax working pressure (bar)AccuracyNumber of pulsesWeight
8732F 1/2″ BSP35+5°C / + 110°C100+/- 0,5%100/l1.5 kg
Electronic oval gears flow meter with pulse transmitter

Art. 2717

Electronic oval gears flow meter with pulse transmitter, body in IXEF, including a stainless steel solenoid valve; suitable for the use with water-based fluids and AdBlue® (DEF). Appropriate to the use in combination with electronic oil monitoring systems by the use of an external receiver.

Art.ConnectionsMax flow (l/min)Operating temperature rangeMax working pressure (bar)AccuracyNumber of pulsesWeight
2717M 1/2″ BSP35+5°C / + 70°C30+/- 0,5%78/l0,6 kg
art 8874 flexbimec

Art. 8874

FLUID KEEPER 8 MULTIDISPENSE monitoring software for Windows® operating systems + interface unit with 230 VAC power supply module, cable and plug. One software and interface unit is necessary for the complete system.

Remote display connected to the pulse meter by cable

Art. 8760

Remote display connected to the pulse meter by cable to visualize the batch of dispensed fluid. The batch is set to zero after a settable time-out expiring.

Art. 8761

Remote display as art. no. 8760 connected to the pulse meter by cable and solenoid valve. The batch is set to zero once the valve will shut-off the fluid passage.

art 8892 flexbimec

Art. 8892

Control unit FLUID KEEPER 20 with alphanumeric keyboard, big display for an improved visualization and thermal printer for printing a ticket of each individual dispense. Includes an internal memory. One control unit is necessary per 8 dispensing points and allows also simultaneous dispensing in various dispensing points. There can be installed up to 16 control units in the system, permitting like that to monitor up to 128 dispensing points. The control unit requires a power supply through the transformer / stabilizer 110-230 VAC – 24 VDC, 7,5 A, IP 55, art.no. 6532.
Art. 8891 Control unit such as art.no. 8892, but without thermal printer.

art 8890 flexbimec Controller Fluid Keeper 20

Art. 8890

Controller Fluid Keeper 20:
– processor ARM with 2 core CORTEX-A72 with 1.6 GHz and 4 core CORTEX-A53 with
1.26 GHz with 4 GB memory RAM LPDDR4
– CAN BUS
– Power supply 110/230 VAC
– USB port
– 16 GB memory
– Ethernet output 10/100/1000 GB
– Dissipator + integrated fan
– Operating temperature from -30°C to +85° C.

Art. 8893

FLUID KEEPER 20 monitoring software on USB flash drive, for a software installation on each device used by operators.

Electronic dosing unit AUTOMATC FILLS

Art. 8857

Electronic dosing unit AUTOMATC FILLS, prepared for the preset of 4 different modifiable quantities of a fluid lubricant that shall be dispensed

Art. 8864

Electronic dosing unit AUTOMATC FILLS, touch screen version.

Art. 8867

Kit composed of:
– 1 electronic dosing unit AUTOMATIC FILLS, art. no. 8857;
– 1 electronic oval gears flow meter with pulse transmitter, 24 VDC – solenoid valve, inline filter and wall bracket, art. no. 8730;
– 1 transformer / stabilizer 230 VAC – 12 VDC, art. no. 6528;
– 1 remote control switchboard, art. no. 7383.

FLUID KEEPER 8 MULTIEROGAZIONE art 8878 Flexbimec

Art. 8878

Example of a configuration for a FLUID KEEPER 8 MULTIDISPENSE system for 8 dispensing points. Basic composition:
– 8 pcs. art. no. 8730
– 1 pc. art. no. 6532
– 1 pc. art. no. 8876
– 5 m of art. no. 8815
– 20 m art. no. 8803
– 1 pc. of art. no. 8874

Art. 8841

Electronic dosing unit CONTROLLER 5.0. Technical features:
– big graphic backlit display;
– bi-directional, serial and cable-based communication with connected printers or PC through USB and serial connections;
– watch with buff er battery;
– storage of the following dispenses data: quantity, ID, date, time;
– integrated power supply 110/230 VAC – 24 VDC;
– possibility of calibration;
– default dispense activation button;
– new dispense quantity selection button.

Art. 8798
Thermal printer, can be connected to the CAN BUS of the control unit. Required for printing a ticket of each individual dispense.
Art. 8730
Electronic oval gears flow meter with pulse transmitter, connections 1/2” BSP (F), suitable for oil, diesel and antifreeze, including a 24 VDC – solenoid valve, an in-line 150 μm cartridge filter and a wall bracket.

Configurazione base del sistema FLUID KEEPER INOX per 4 punti di erogazione.

Art. 8873

Example of a configuration for a FLUID KEEPER INOX MULTIDISPENSE system for 4 dispensing points. Basic composition:
– 4 pcs. art. no. 2717
– 1 pc. art. no. 6532
– 1 pc. art. no. 8876
– 1 pc. art. no. 8806
– 5 m of art. no. 8815
– 5 m art. no. 8803
– 1 pc. of art. no. 8874